This Category 6 solid-state building entrance protector is a great choice for protecting high-performance 4-pair Cat6 outside plant cables and Cat6 UTP cables in voice or ISDN low voltage (digital, 75V) applications. It uses 110 punchdown in/out. With a recommended grounding impedance of <.5 ohm, it features signal perfect circuitry and is fused. The clamping level is 75V, response time is 1 - 5 nanoseconds, and it protects 4-pairs of wires. You can expand system protection by attaching SurgeGate Modules to one another.


To use this protector, first make sure your grounding impedance is less than 0.5 ohm. Connect the high - performance 4 - pair Cat6 outside plant cables or Cat6 UTP cables using the 110 punchdown in/out. It's designed to protect cables in voice or ISDN low voltage applications. Remember, it has a clamping level of 75V, so avoid exposing it to voltages higher than that. In terms of maintenance, check the fuse regularly. If the protector doesn't seem to be working properly, the fuse might be the issue. You can expand the system protection by attaching SurgeGate Modules together. Just follow the connection instructions for the modules. Keep the protector in a dry and cool place to ensure its long - term performance.